CO2 Characterization (using 16g tank)
Distance (in) (0 Degrees) Result
5 instant extinguish15 instant extinguish
25 instant extinguish
(canister low on CO2) 30 no extinguish
(canister low on CO2) 35 no extinguish
30 instant extinguish
35 instant extinguish
40 instant extinguish
12'' angle test
Degrees from flame Result
0 instant extinguish5 instant extinguish
10 instant extinguish
15 2 pulses to extinguish (still nearly instant)
20 3 pulses and no extinguish
From this data, it can be observed that while the CO2 provides a quick extinguish, if the canister is not full or accidentally discharges some of its load in the wrong direction, after only 3 short pulses the CO2 canister did not have enough gas to blow out the candle.